One-Piece and Two-Piece Rotary Coolant Gland Dimensions, Break-In Steps & Operating Tips
A rotary coolant gland only works if it sits correctly on the tool holder shank. The shank diameter, groove diameter, and bearing width all have to match the gland, or you risk leaks, uneven wear, and premature failure. This guide collects the mounting dimensions for George Whalley Company standard and high-RPM one-piece glands and high-RPM two-piece glands, then walks through the recommended break-in procedure and operating conditions.
In this guide:
- Shank mounting dimensions for one-piece glands (CGH / CGS)
- Shank mounting dimensions for two-piece high-RPM glands (CGH2 / 801 series)
- How to match a shank to the right gland
- The break-in procedure and recommended operating conditions
What the shank mounting dimensions mean
Each table below lists the shank outside diameter (A) and the machined features the gland locates on. Dimensions are in inches. Where two values are shown, they are the limits printed in the manufacturer’s catalog.
| Letter | Dimension | What it tells you |
|---|---|---|
| A | Shank O.D. | The outside diameter of the tool holder shank the gland rides on. |
| B | Snap ring groove O.D. / O-ring groove O.D. | The diameter at the bottom of the groove cut into the shank. One-piece glands use snap ring grooves; two-piece glands use O-ring grooves. |
| C | Gland bearing width | The length of shank the gland bearing sits on. |
| D | Snap ring width / O-ring width | The width of the snap ring or O-ring that locates the gland. |
| F | Set screw point location | Two-piece glands only. Where the set screw point lands on the shank. |
One-piece rotary coolant glands (standard and high RPM)
One-piece glands mount on a shank with snap ring grooves. Find your shank O.D. in column A, then confirm the groove O.D., bearing width, and snap ring width before ordering the gland number in the last column.
| A Shank O.D. |
B Snap ring groove O.D. |
C Gland bearing width |
D Snap ring width |
For use with coolant gland no. |
|---|---|---|---|---|
| 0.9360 / 0.9340 | 0.8790 / 0.8850 | 1.380 / 1.385 | 0.046 / 0.048 | CGH/CGS-0937 |
| 1.249 / 1.247 | 1.172 / 1.180 | 1.380 / 1.385 | 0.056 / 0.060 | CGH/CGS-1250 |
| 1.624 / 1.622 | 1.524 / 1.534 | 1.630 / 1.635 | 0.068 / 0.072 | CGH/CGS-1625 |
| 2.249 / 2.247 | 2.114 / 2.126 | 1.815 / 1.820 | 0.086 / 0.091 | CGH/CGS-2250 |
| 2.749 / 2.747 | 2.596 / 2.608 | 1.755 / 1.760 | 0.103 / 0.108 | CGH/CGS-2750 |
| 3.499 / 3.497 | 3.310 / 3.322 | 1.815 / 1.820 | 0.103 / 0.108 | CGH-3500 |
| 3.999 / 3.997 | 3.786 / 3.798 | 2.002 / 2.006 | 0.120 / 0.125 | CGH-4000 |
Two-piece high-RPM rotary coolant glands
Two-piece high-RPM glands mount on a shank with O-ring grooves. This table adds dimension F, the set screw point location, which one-piece glands do not specify.
| A Shank O.D. |
B O-ring groove O.D. |
C Gland bearing width |
D O-ring width |
F Set screw point location |
For use with coolant gland no. |
|---|---|---|---|---|---|
| 1.249 / 1.247 | 1.135 | 1.000 | 0.090 / 0.094 | 0.906 | CGH2-0937 |
| 1.499 / 1.497 | 1.380 | 1.000 | 0.090 / 0.094 | 1.000 | CGH2-1250 |
| 1.999 / 1.997 | 1.885 | 1.250 | 0.090 / 0.094 | 1.063 | CGH2-1625 |
| 2.561 / 2.559 | 2.375 | 1.500 | 0.138 / 0.142 | 1.188 | CGH2-2250 |
| 4.249 / 4.247 | 4.025 | 1.500 | 0.175 / 0.185 | 1.531 | CGH2-2750 |
| 1.999 / 1.997 | 1.885 | 1.250 | 0.090 / 0.094 | 0.906 | 801-083A |
| 2.449 / 2.497 | 2.390 | 1.500 | 0.090 / 0.094 | 0.969 | 801-091 |
How to match a shank to the right gland
- Measure the shank O.D. and find the matching row in column A for the gland style you are using (one-piece or two-piece).
- Check the groove. The snap ring or O-ring groove O.D. (B) and width (D) on your shank should match the row.
- Check the bearing width (C) so the gland bearing has the shank length it needs.
- For two-piece glands, confirm the set screw point location (F).
- Use the gland number in the last column for that row.
Break-in procedure for high-RPM coolant glands
Break-in assures proper lubrication, even wear, and proper seating. The pressure is kept lower at first to avoid overloading the seals.
- Run the gland at 100 RPM for 3 minutes with coolant introduced at a pressure and volume between 100 psi and 500 psi.
- Repeat the procedure at 500 RPM for 3 minutes.
- Repeat it again at 1000 RPM.
- Once break-in is complete, the unit can run at pressures between 100 psi and 750/1000 psi. The catalog gives both maximums, so confirm which applies to your gland model.
Operating conditions for maximum gland and seal life
Four conditions are recommended to get the most life and performance from coolant glands and seals:
1. Coolant filtration
Filter to 30 to 50 micron at a minimum. 5 micron is optimum.
2. Coolant type and viscosity
A good water-soluble synthetic is preferred, with good lubrication and heat dissipation under pressure.
3. Coolant pressure
Run a minimum of 100 psi at high RPM (1800 SFM or more, based on the gland I.D. or the O.D. bearing diameter of the tool holder). Maximum pressure is 750/1000 psi.
4. Coolant volume
Volume must be enough to properly lubricate the cutting tool, as its manufacturer recommends. Volume and pressure combined cannot exceed the coolant orifice delivery capability of your tool, or the gland can fail early from excess heat buildup.
Source: George Whalley Company Coolant-Fed Tooling & Systems catalog, shank mounting specifications and operating recommendations. Always confirm dimensions against the current catalog or drawing before machining a shank.
Ready to find the right tooling for your shop?
Request the full CFT Coolant-Fed Tooling & Systems catalog.
Request a Catalog →- CFT Coolant-Fed Drills
- When & Why To Use Coolant Fed Drills (Travers Tool)
Frequently asked questions
How do I choose the right coolant gland for my tool holder shank?
Measure the shank outside diameter and find the matching row in column A of the table for your gland style. The last column gives the gland number to use with that shank. Then confirm the groove diameter and widths match your shank.
What is the difference between one-piece and two-piece rotary coolant glands?
In this catalog, one-piece glands (CGH/CGS) mount using snap ring grooves on the shank. The high-RPM two-piece glands (CGH2 and 801 series) mount using O-ring grooves and also specify a set screw point location.
How do you break in a high-RPM coolant gland?
Run the gland at 100 RPM for 3 minutes with coolant between 100 and 500 psi. Repeat at 500 RPM for 3 minutes, then again at 1000 RPM. After that, the unit can run at pressures between 100 psi and 750/1000 psi.
What coolant filtration does a rotary coolant gland need?
The recommendation is 30 to 50 micron filtration at a minimum, with 5 micron filtration being optimum.
What coolant pressure should I run through a coolant gland?
Use at least 100 psi at high RPM (1800 SFM or more, based on the gland I.D. or the O.D. bearing diameter of the tool holder). The maximum is 750/1000 psi.